Home/ Directory/ ND/ CENTRAL PLAINS WATER DISTRICT

Water system · PWSID ND5201309

CENTRAL PLAINS WATER DISTRICT

100
Excellent
PurityRadar safety score

PWSID

ND5201309

State

North Dakota

City

FESSENDEN

Population served

3,504

Primary source

Groundwater

Score history

No change since tracking began Jun 18, 2026.

Jun 18, 2026 · score 100 Jun 18, 2026 · score 100

2 score updates logged since tracking began Jun 18, 2026. Each future EPA re-score adds a point.

PFAS & contaminant readings

Latest detections from EPA’s UCMR5 monitoring (through Sep 2025). Levels in parts per trillion (ppt).

Lithium

92,200 ppt

limit —

No federal limit

PFBA

7.1 ppt

limit —

No federal limit

Violations & enforcement

5

Violations on record

0

Unaddressed

4

Health-based

12

Enforcement actions

From EPA ECHO (SDWIS), most recent enforcement Jun 2011. Official EPA record →

Other · EPA contaminant 7500 began Jul 2005 Resolved
Max contaminant level (MCL) · Haloacetic acids (HAA5) health-based began Jul 2005 Resolved
Max contaminant level (MCL) · Total trihalomethanes (TTHM) health-based began Apr 2005 Resolved
Max contaminant level (MCL) · Haloacetic acids (HAA5) health-based began Apr 2005 Resolved
Max contaminant level (MCL) · Haloacetic acids (HAA5) health-based began Jan 2005 Resolved

Recent enforcement actions

  • State action · SO6 Jun 2011
  • State action · SOX Nov 2006
  • State action · SIF Oct 2005
  • State action · SIE Oct 2005
  • State action · SIA Oct 2005
  • State action · SIA Aug 2005
  • State action · SIF Jul 2005
  • State action · SIA Jul 2005

Area water-quality monitoring

Environmental monitoring (rivers, wells, intakes) recorded in this system’s service area in the EPA/USGS Water Quality Portal since 2018 — source/ambient water, not finished tap water. Context for the watershed, not a reading from your tap.

ContaminantMedian · max · samples

Fluoride

2 stations · latest Oct 2023

0.27 · max 0.35 mg/l · 26

Manganese

2 stations · latest Oct 2023

85.5 · max 271 ug/l · 21

Arsenic

1 station · latest Aug 2023

5.95 · max 8.4 ug/l · 8

Copper

1 station · latest Jun 2021

5.66 · max 5.66 ug/L · 1

Source: Water Quality Portal (EPA/USGS/state agencies). Values are as-reported and aren’t health thresholds.

This profile is built from EPA public records for system ND5201309 — SDWIS violations and UCMR5 PFAS sampling. The score is system-level and can’t account for your home’s plumbing (older pipes can add lead at the tap). For health decisions, check your exact address, read the utility’s Consumer Confidence Report, and confirm with your provider.